Full Record for Micrograph 790
[431 KB]
View micrograph
.. in new window
View micrograph and record
.. in new window
|
- Micrograph no
- 790
- Brief description
- Austempered ductile cast iron
- Keywords
- alloy
, austempering , carbon, cast iron , copper, ductile , ferrite , graphite , iron, manganese, metal, molybdenum, pearlite , silicon 
- Categories
- Metal or alloy
- System
- Fe-C-X
- Composition
- Fe, C 3.52, Si 2.51, Mn 0.49, Mo 0.15, Cu 0.31 (wt%)
- Standard codes
- Reaction
- Processing
- Applications
- Sample preparation
- Etchant: Nital 2%
- Technique
- Reflected light microscopy
- Length bar
- 20 μm
- Further information
- Austenitised at 950°C, austempered at 350°C for 64 min.
Source: http://www.msm.cam.ac.uk/phase-trans/2001/adi/adimore.html.
- Contributor
- Dr M A Yescas-Gonzalez
- Organisation
- Department of Materials Science and Metallurgy, University of Cambridge
- Date
- 18/07/03
- Licence for re-use